Difference between revisions of "Talk:4000XL wiring"
From Batchelor-s
Jump to navigationJump to searchm |
m |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Generac 84132 Voltage Regulator | + | Generac 84132 Voltage Regulator |
+ | |||
+ | *From [http://www.smokstak.com/forum/showthread.php?t=95314 www.smokstak.com/forum/] | ||
+ | *The 84132 Power Regulator Board was reverse-engineered by Warren914 | ||
+ | *[http://members.rennlist.org/warren/generac84132.pdf generac84132.pdf] | ||
Line 22: | Line 26: | ||
− | C1 104K/250V at SCR-1 anode - same as [[1-BLK]] | + | *C1 104K/250V at SCR-1 anode - same as [[1-BLK]] |
− | [[P1-2]] Feedback to [[AVR]] ------------> | + | *[[P1-2]] Feedback to [[AVR]] ------------> |
− | R2 68K 1/4W | + | *R2 68K 1/4W |
− | GND | + | *GND |
+ | |||
+ | |||
+ | *[[P1-1]] Shield - ground | ||
+ | *[[P1-2]] Feedback to [[AVR]] ------------> | ||
+ | *[[P1-3]] Gate from [[AVR]] <----------- | ||
− | + | -- | |
− | |||
− |
Latest revision as of 09:43, 21 February 2014
Generac 84132 Voltage Regulator
- From www.smokstak.com/forum/
- The 84132 Power Regulator Board was reverse-engineered by Warren914
- generac84132.pdf
rotating field
stator is outside non moving coils
The DPE winding is a coil that generates a pulse for the Field winding.
The duration of the current is controlled by an SCR-1
The voltage regulator controls the signal to the SCR-1 and therefore controls the Field current and output voltage.
Diode D2 allows only positive voltage to go through the Field winding.
The MOV-1 across the Field winding suppresses transients.
D1 R3 R1 sets a default current
- D1 1N4007
- R3 18K 1/2W
- R1 47K 1/4W
--